Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 383.491
Filtrar
1.
Sci Rep ; 14(1): 8372, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600311

RESUMO

Rib fractures are highly predictive of non-accidental trauma in children under 3 years old. Rib fracture detection in pediatric radiographs is challenging because fractures can be obliquely oriented to the imaging detector, obfuscated by other structures, incomplete, and non-displaced. Prior studies have shown up to two-thirds of rib fractures may be missed during initial interpretation. In this paper, we implemented methods for improving the sensitivity (i.e. recall) performance for detecting and localizing rib fractures in pediatric chest radiographs to help augment performance of radiology interpretation. These methods adapted two convolutional neural network (CNN) architectures, RetinaNet and YOLOv5, and our previously proposed decision scheme, "avalanche decision", that dynamically reduces the acceptance threshold for proposed regions in each image. Additionally, we present contributions of using multiple image pre-processing and model ensembling techniques. Using a custom dataset of 1109 pediatric chest radiographs manually labeled by seven pediatric radiologists, we performed 10-fold cross-validation and reported detection performance using several metrics, including F2 score which summarizes precision and recall for high-sensitivity tasks. Our best performing model used three ensembled YOLOv5 models with varied input processing and an avalanche decision scheme, achieving an F2 score of 0.725 ± 0.012. Expert inter-reader performance yielded an F2 score of 0.732. Results demonstrate that our combination of sensitivity-driving methods provides object detector performance approaching the capabilities of expert human readers, suggesting that these methods may provide a viable approach to identify all rib fractures.


Assuntos
Radiologia , Fraturas das Costelas , Humanos , Criança , Pré-Escolar , Fraturas das Costelas/diagnóstico por imagem , Fraturas das Costelas/etiologia , Radiografia , Redes Neurais de Computação , Radiologistas , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
J Ovarian Res ; 17(1): 78, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600539

RESUMO

BACKGROUND: This study investigated the association between Anti-Müllerian Hormone (AMH) and relevant metabolic parameters and assessed its predictive value in the clinical diagnosis of polycystic ovarian syndrome (PCOS). METHODS: A total of 421 women aged 20-37 years were allocated to the PCOS (n = 168) and control (n = 253) groups, and their metabolic and hormonal parameters were compared. Spearman correlation analysis was conducted to investigate associations, binary logistic regression was used to determine PCOS risk factors, and receiver operating characteristic (ROC) curves were generated to evaluate the predictive value of AMH in diagnosing PCOS. RESULTS: The PCOS group demonstrated significantly higher blood lipid, luteinizing hormone (LH), and AMH levels than the control group. Glucose and lipid metabolism and hormonal disorders in the PCOS group were more significant than in the control group among individuals with and without obesity. LH, TSTO, and AMH were identified as independent risk factors for PCOS. AMH along with LH, and antral follicle count demonstrated a high predictive value for diagnosing PCOS. CONCLUSION: AMH exhibited robust diagnostic use for identifying PCOS and could be considered a marker for screening PCOS to improve PCOS diagnostic accuracy. Attention should be paid to the effect of glucose and lipid metabolism on the hormonal and related parameters of PCOS populations.


Assuntos
Hormônio Antimülleriano , Síndrome do Ovário Policístico , Feminino , Humanos , Hormônio Antimülleriano/sangue , Glucose/metabolismo , Hormônio Luteinizante/sangue , Síndrome do Ovário Policístico/sangue , Síndrome do Ovário Policístico/metabolismo , Síndrome do Ovário Policístico/patologia , Sensibilidade e Especificidade , Adulto
3.
Zhonghua Zhong Liu Za Zhi ; 46(4): 354-364, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644271

RESUMO

Objective: To determine the total and age-specific cut-off values of total prostate specific antigen (tPSA) and the ratio of free PSA divided total PSA (fPSA/tPSA) for screening prostate cancer in China. Methods: Based on the Chinese Colorectal, Breast, Lung, Liver, and Stomach cancer Screening Trial (C-BLAST) and the Tianjin Common Cancer Case Cohort (TJ4C), males who were not diagnosed with any cancers at baseline since 2017 and received both tPSA and fPSA testes were selected. Based on Cox regression, the overall and age-specific (<60, 60-<70, and ≥70 years) accuracy and optimal cut-off values of tPSA and fPSA/tPSA ratio for screening prostate cancer were evaluated with time-dependent receiver operating characteristic curve (tdROC) and area under curve (AUC). Bootstrap resampling was used to internally validate the stability of the optimal cut-off value, and the PLCO study was used to externally validate the accuracy under different cut-off values. Results: A total of 5 180 participants were included in the study, and after a median follow-up of 1.48 years, a total of 332 prostate cancer patients were included. In the total population, the tdAUC of tPSA and fPSA/tPSA screening for prostate cancer were 0.852 and 0.748, respectively, with the optimal cut-off values of 5.08 ng/ml and 0.173, respectively. After age stratification, the age specific cut-off values of tPSA in the <60, 60-<70, and ≥70 age groups were 3.13, 4.82, and 11.54 ng/ml, respectively, while the age-specific cut-off values of fPSA/tPSA were 0.153, 0.135, and 0.130, respectively. Under the age-specific cut-off values, the sensitivities of tPSA screening for prostate cancer in males <60, 60-70, and ≥70 years old were 92.3%, 82.0%, and 77.6%, respectively, while the specificities were 84.7%, 81.3%, and 75.4%, respectively. The age-specific sensitivities of fPSA/tPSA for screening prostate cancer were 74.4%, 53.3%, and 55.9%, respectively, while the specificities were 83.8%, 83.7%, and 83.7%, respectively. Both bootstrap's internal validation and PLCO external validation provided similar results. The combination of tPSA and fPSA/tPSA could further improve the accuracy of screening. Conclusion: To improve the screening effects, it is recommended that age-specific cut-off values of tPSA and fPSA/tPSA should be used to screen for prostate cancer in the general risk population.


Assuntos
Detecção Precoce de Câncer , Antígeno Prostático Específico , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/sangue , Antígeno Prostático Específico/sangue , Idoso , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Fatores Etários , Curva ROC , China , Sensibilidade e Especificidade , Programas de Rastreamento/métodos , Área Sob a Curva
4.
Zhonghua Fu Chan Ke Za Zhi ; 59(4): 270-278, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38644273

RESUMO

Objective: To analyze serum bile acid profiles in pregnant women with normal pregnancy, intrahepatic cholestasis of pregnancy (ICP) and asymptomatic hypercholanemia of pregnancy (AHP), and to evaluate the application value of serum bile acid profiles in the diagnosis of ICP and AHP. Methods: The clinical data of 122 pregnant women who underwent prenatal examination in Xuzhou Maternal and Child Health Care Hospital from June 2022 to May 2023 were collected, including 54 cases of normal pregnancy group, 28 cases of ICP group and 40 cases of AHP group. Ultraperformance liquid chromatography-tandem mass spectrometry was used to measure the levels of 15 serum bile acids in each group, including cholic acid (CA), chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), lithocholic acid (LCA), ursodeoxycholic acid (UDCA), glycolcholic acid (GCA), glycochenodeoxycholic acid (GCDCA), glycodeoxycholic acid (GDCA), glycolithocholic acid (GLCA), glycoursodeoxycholic acid (GUDCA), taurocholic acid (TCA), taurochenodeoxycholic acid (TCDCA), taurodeoxycholic acid (TDCA), taurolithocholic acid (TLCA) and tauroursodeoxycholic acid (TUDCA). Principal component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA) were used to screen differential bile acids. The receiver operating characteristic (ROC) curve was used to analyze the diagnostic efficacy of differential bile acids and combined indicators between groups. Results: (1) Compared with normal pregnancy group, the serum levels of LCA, GCA, GCDCA, GDCA, GLCA, UDCA, TCA, TCDCA, TDCA, TLCA, GUDCA and TUDCA in ICP group were significantly different (all P<0.05), while the levels of LCA, DCA, GCA, GCDCA, GDCA, GLCA, TCA, TCDCA, TDCA, TLCA, GUDCA and TUDCA in AHP group were significantly different (all P<0.05). Compared with ICP group, the serum levels of CDCA, DCA, UDCA, TDCA, GUDCA and TUDCA in AHP group were significantly different (all P<0.05). (2) In the OPLS-DA model, the differential bile acids between ICP group and AHP group were TUDCA, TCA, UDCA, GUDCA and GCA, and their variable importance in projection (VIP) were 1.489, 1.345, 1.344, 1.184 and 1.111, respectively. TCA, GCDCA, GCA, TDCA, GDCA and TCDCA were the differentially expressed bile acids between AHP group and normal pregnancy group, and their VIP values were 1.236, 1.229, 1.197, 1.145, 1.139 and 1.138, respectively. (3) ROC analysis showed that the area under the curve (AUC) of TUDCA, TCA, UDCA, GUDCA and GCA in the differential diagnosis of ICP and AHP was 0.860, and the sensitivity and specificity were 67.9% and 95.0%, respectively. The AUC of TCA, GCDCA, GCA, TDCA, GDCA and TCDCA in the diagnosis of AHP was 0.964, and the sensitivity and specificity were 95.0% and 93.1%, respectively. Conclusions: There are differences in serum bile acid profiles among normal pregnant women, ICP and AHP. The serum bile acid profiles of pregnant women have potential application value in the differential diagnosis of ICP and AHP and the diagnosis of AHP.


Assuntos
Ácidos e Sais Biliares , Colestase Intra-Hepática , Complicações na Gravidez , Humanos , Feminino , Gravidez , Colestase Intra-Hepática/sangue , Colestase Intra-Hepática/diagnóstico , Ácidos e Sais Biliares/sangue , Complicações na Gravidez/sangue , Complicações na Gravidez/diagnóstico , Adulto , Espectrometria de Massas em Tandem/métodos , Sensibilidade e Especificidade , Curva ROC
5.
Zhonghua Fu Chan Ke Za Zhi ; 59(4): 279-287, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38644274

RESUMO

Objective: To evaluate the diagnostic efficiency of copy number variation sequencing (CNV-seq) to detect the deletion or duplication of DMD gene in prenatal diagnosis. Methods: A retrospective analysis was carried out on the CNV-seq results of 34 544 fetuses diagnosed in the First People's Hospital of Yunnan Province from January 2018 to July 2023. A total of 156 cases of fetuses were collected, including Group 1:125 cases with family history of Duchenne muscular dystrophy or Becker muscular dystrophy (DMD/BMD), and Group 2:31 cases with no family history but a DMD gene deletion or duplication was detected unexpectedly by CNV-seq. Multiplex ligation-dependent probe amplification (MLPA) was used as a standard method to detect the deletion or duplication. Consistency test was carried out basing on the results of CNV-seq and MLPA of all 156 cases. Results: Comparing to MLPA, CNV-seq had a coincidence rate of 92.3% (144/156) for DMD gene deletion or duplication, with a sensitivity and positive predictive value of 88.2%, with a specificity and negative predictive value of 94.3%, a missed detection rate of 3.8%, and a Kappa value of 0.839. CNV-seq missed 4 cases with deletions and 2 with duplications due to involved fragments less than 100 Kb, among 20 cases of deletions and 6 cases of duplications detected by MLPA in Group 1. In Group 2, the deletions and duplications detected by CNV-seq were 42% (13/31) and 58% (18/31), respectively, in which the percentage of duplication was higher than that in Group 1. Among those 18 cases with duplications, 3 cases with duplication locating in exon 42~67 were likely pathogenic; while 9 cases with duplication covering the 5' or 3' end of the DMD gene, containing exon 1 or 79 and with only one breakpoint within the gene, along with the last 6 cases with duplications locating at chrX: 32650635_32910000 detected only by CNV-seq, which might be judged as variants of uncertain significance. Conclusions: CNV-seq has a good efficiency to detect fetal DMD gene deletion or duplication in prenatal diagnosis, while a further verification test by MLPA is recommended. The duplications on chrX: 32650635_32910000, 5' or 3' end of DMD gene detected by CNV-seq should be carefully verified and assessed because those variants appear to be nonpathogenic polymorphisms.


Assuntos
Variações do Número de Cópias de DNA , Deleção de Genes , Duplicação Gênica , Distrofia Muscular de Duchenne , Diagnóstico Pré-Natal , Humanos , Diagnóstico Pré-Natal/métodos , Gravidez , Feminino , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/diagnóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Distrofina/genética , Feto/anormalidades , Reação em Cadeia da Polimerase Multiplex/métodos
6.
Zhonghua Fu Chan Ke Za Zhi ; 59(4): 299-306, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38644276

RESUMO

Objective: To explore the value of optical coherence tomography (OCT) imaging system in evaluating cervical lesions in vivo. Methods: A total of 1 214 patients with cervical lesions were collected from January 2020 to December 2021 in the Third Affiliated Hospital of Zhengzhou University, Maternal and Chlid Heaith Hospital of Gushi County, Xinyang City, Henan Province, and Maternal and Chlid Heaith Hospital of Sui County, Shangqiu City, Henan Province. The age of the patients was (38.9±10.5) years (range: 16-77 years). All patients underwent in vivo cervical OCT examination and cervical biopsy pathology examination, and summarized the OCT image features of in vivo cervical lesions. Using the pathological diagnosis as the "gold standard", the accuracy, specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) of OCT image interpretation results were evaluated, as well as the consistency of OCT image diagnosis and pathological diagnosis. At the same time, the in vivo cervical OCT imaging system, as a newly developed screening tool, was compared with the traditional combined screening of human papillomavirus (HPV) and Thinprep cytologic test (TCT), to assess the screening effect. Results: By comparing the OCT images of the cervix in vivo with the corresponding HE images, the OCT image characteristics of the normal cervix and various types of cervical lesions in vivo were summarized. The accuracy, sensitivity, specificity, PPV and NPV of OCT image in the diagnosis of high-grade squamous intraepithelial lesion (HSIL) and above (HSIL+) were 93.4%, 88.5%, 95.0%, 85.0% and 96.2%, respectively. The accuracy, sensitivity, specificity, PPV and NPV of OCT for low-grade squamous intraepithelial lesion (LSIL) were 84.7%, 61.7%, 96.3%, 89.3% and 83.2%, respectively. The consistency between OCT image diagnosis and pathological diagnosis was strong (Kappa value was 0.701).The accuracy, sensitivity and specificity of OCT screening, HPV and TCT combined screening were 83.7% vs 64.9% (χ²=128.82, P<0.001), 77.8% vs 64.5% (χ²=39.01, P<0.001), 91.8% vs 65.4% (χ²=98.12, P<0.001), respectively. The differences were statistically significant. Conclusions: OCT imaging system has high sensitivity and specificity in the evaluation of cervical lesions in vivo, and has the characteristics of non-invasive, real-time and high efficiency. OCT examination is expected to become an effective method for the diagnosis of cervical lesions and cervical cancer screening.


Assuntos
Colo do Útero , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Neoplasias do Colo do Útero , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Adulto , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/diagnóstico , Pessoa de Meia-Idade , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Adolescente , Idoso , Displasia do Colo do Útero/diagnóstico por imagem , Displasia do Colo do Útero/patologia , Displasia do Colo do Útero/diagnóstico , Infecções por Papillomavirus/diagnóstico , Adulto Jovem , Esfregaço Vaginal , Biópsia , Valor Preditivo dos Testes , Detecção Precoce de Câncer/métodos
9.
Cephalalgia ; 44(4): 3331024241248210, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38663903

RESUMO

BACKGROUND: Headache burden is substantial in idiopathic intracranial hypertension. The classification of idiopathic intracranial hypertension headache by the International Classification of Headache Disorders (ICHD) is an important tool for research and clinical purposes. METHODS: We phenotyped headaches and tested sensitivity and specificity of the ICHD-3 criteria for idiopathic intracranial hypertension headache in a prospective cohort of patients suspected of idiopathic intracranial hypertension at two tertiary headache centers. RESULTS: Sensitivity was 93% and specificity was 100% of ICHD-3 criteria for idiopathic intracranial hypertension-related headache validated in idiopathic intracranial hypertension (n = 140) and patients in whom idiopathic intracranial hypertension was suspected but disproven (n = 103). The phenotype of new/worsened headaches related to idiopathic intracranial hypertension suspicion was equally migraine-like (p = 0.76) and tension-type-like (p = 0.08). Lumbar puncture opening pressure was higher (p < 0.0001) and pulsatile tinnitus more frequent (p < 0.0001) in idiopathic intracranial hypertension patients, but neither improved the applicability of the headache criteria, nor did papilledema. CONCLUSION: Headache phenotype is not distinct in idiopathic intracranial hypertension. ICHD-3 criteria for idiopathic intracranial hypertension headache are sensitive and specific, but simplicity can be improved without compromising accuracy. We propose that a new or worsened headache temporally related to active idiopathic intracranial hypertension is a sufficient criterion for idiopathic intracranial hypertension headache regardless of headache phenotype or accompanying symptoms, and that elements of idiopathic intracranial hypertension diagnostics (papilledema and opening pressure) be segregated from headache criteria.Trial Registration: ClinicalTrials.gov Identifier: NCT04032379.


Assuntos
Cefaleia , Fenótipo , Pseudotumor Cerebral , Sensibilidade e Especificidade , Humanos , Feminino , Masculino , Adulto , Pseudotumor Cerebral/diagnóstico , Pseudotumor Cerebral/complicações , Cefaleia/diagnóstico , Cefaleia/classificação , Cefaleia/etiologia , Pessoa de Meia-Idade , Classificação Internacional de Doenças , Estudos Prospectivos
10.
Ann Clin Microbiol Antimicrob ; 23(1): 37, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664821

RESUMO

PURPOSE: Group B Streptococcus (GBS) is the leading cause of invasive infections in newborns. The prevention of GBS neonatal disease relies on the administration of an intrapartum antibiotic prophylaxis to GBS-colonized women. In recent years, rapid intrapartum detection of GBS vaginal colonization using real-time nucleic acid amplification tests (NAATs) emerged as an alternative to antenatal culture screening methods. METHODS: We compared the performances of two loop-mediated isothermal amplification (LAMP) tests, the Ampliflash® GBS and the PlusLife® GBS tests, to standard culture for GBS detection in vaginal specimens from pregnant women. The study was conducted from April to July 2023 in a French hospital of the Paris area. RESULTS: A total of 303 samples were analyzed, including 85 culture-positive samples (28.1%). The Ampliflash® GBS test and the PlusLife® GBS tests gave a result for 100% and 96.3% tests, respectively. The performances of the tests were as follows: sensitivity 87.1% (95% confidence interval (CI) 78.3-92.6) and 98.7% (95% CI 93.0-99.8), specificity 99.1% (95% CI 96.7-99.8), and 91.9% (95% CI 87.3-95.0), respectively. False negative results of the Ampliflash® GBS test correlated with low-density GBS cultures. Time-to-results correlated with GBS culture density only for the PlusLife® GBS test (p < 0.001). CONCLUSION: Both techniques provide excellent analytical performances with high sensitivity and specificity together with a short turnaround time and results available in 10 to 35 min. Their potential to further reduce the burden of GBS neonatal disease compared with antenatal culture screening needs to be assessed in future clinical studies.


Assuntos
Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Complicações Infecciosas na Gravidez , Sensibilidade e Especificidade , Infecções Estreptocócicas , Streptococcus agalactiae , Vagina , Humanos , Feminino , Técnicas de Amplificação de Ácido Nucleico/métodos , Streptococcus agalactiae/genética , Streptococcus agalactiae/isolamento & purificação , Gravidez , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/microbiologia , Vagina/microbiologia , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Recém-Nascido , Adulto
11.
J Biomed Opt ; 29(4): 045006, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38665316

RESUMO

Significance: During breast-conserving surgeries, it is essential to evaluate the resection margins (edges of breast specimen) to determine whether the tumor has been removed completely. In current surgical practice, there are no methods available to aid in accurate real-time margin evaluation. Aim: In this study, we investigated the diagnostic accuracy of diffuse reflectance spectroscopy (DRS) combined with tissue classification models in discriminating tumorous tissue from healthy tissue up to 2 mm in depth on the actual resection margin of in vivo breast tissue. Approach: We collected an extensive dataset of DRS measurements on ex vivo breast tissue and in vivo breast tissue, which we used to develop different classification models for tissue classification. Next, these models were used in vivo to evaluate the performance of DRS for tissue discrimination during breast conserving surgery. We investigated which training strategy yielded optimum results for the classification model with the highest performance. Results: We achieved a Matthews correlation coefficient of 0.76, a sensitivity of 96.7% (95% CI 95.6% to 98.2%), a specificity of 90.6% (95% CI 86.3% to 97.9%) and an area under the curve of 0.98 by training the optimum model on a combination of ex vivo and in vivo DRS data. Conclusions: DRS allows real-time margin assessment with a high sensitivity and specificity during breast-conserving surgeries.


Assuntos
Neoplasias da Mama , Mama , Margens de Excisão , Mastectomia Segmentar , Análise Espectral , Humanos , Feminino , Neoplasias da Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Mastectomia Segmentar/métodos , Análise Espectral/métodos , Mama/diagnóstico por imagem , Mama/cirurgia , Sensibilidade e Especificidade
12.
BMC Musculoskelet Disord ; 25(1): 292, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622682

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) can diagnose meniscal lesions anatomically, while quantitative MRI can reflect the changes of meniscal histology and biochemical structure. Our study aims to explore the association between the measurement values obtained from synthetic magnetic resonance imaging (SyMRI) and Stoller grades. Additionally, we aim to assess the diagnostic accuracy of SyMRI in determining the extent of meniscus injury. This potential accuracy could contribute to minimizing unnecessary invasive examinations and providing guidance for clinical treatment. METHODS: Total of 60 (n=60) patients requiring knee arthroscopic surgery and 20 (n=20) healthy subjects were collected from July 2022 to November 2022. All subjects underwent conventional MRI and SyMRI. Manual measurements of the T1, T2 and proton density (PD) values were conducted for both normal menisci and the most severely affected position of injured menisci. These measurements corresponded to the Stoller grade of meniscus injuries observed in the conventional MRI. All patients and healthy subjects were divided into normal group, degeneration group and torn group according to the Stoller grade on conventional MRI. One-way analysis of variance (ANOVA) was employed to compare the T1, T2 and PD values of the meniscus among 3 groups. The accuracy of SyMRI in diagnosing meniscus injury was assessed by comparing the findings with arthroscopic observations. The diagnostic efficiency of meniscus degeneration and tear between conventional MRI and SyMRI were analyzed using McNemar test. Furthermore, a receiver operating characteristic curve (ROC curve) was constructed and the area under the curve (AUC) was utilized for evaluation. RESULTS: According to the measurements of SyMRI, there was no statistical difference of T1 value or PD value measured by SyMRI among the normal group, degeneration group and torn group, while the difference of T2 value was statistically significant among 3 groups (P=0.001). The arthroscopic findings showed that 11 patients were meniscal degeneration and 49 patients were meniscal tears. The arthroscopic findings were used as the gold standard, and the difference of T1 and PD values among the 3 groups was not statistically significant, while the difference of T2 values (32.81±2.51 of normal group, 44.85±3.98 of degeneration group and 54.42±3.82 of torn group) was statistically significant (P=0.001). When the threshold of T2 value was 51.67 (ms), the maximum Yoden index was 0.787 and the AUC value was 0.934. CONCLUSIONS: The measurement values derived from SyMRI could reflect the Stoller grade, illustrating that SyMRI has good consistency with conventional MRI. Moreover, the notable consistency observed between SyMRI and arthroscopy suggests a potential role for SyMRI in guiding clinical diagnoses.


Assuntos
Traumatismos do Joelho , Menisco , Lesões do Menisco Tibial , Humanos , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia , Lesões do Menisco Tibial/patologia , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/cirurgia , Curva ROC , Imageamento por Ressonância Magnética/métodos , Artroscopia/métodos , Meniscos Tibiais/cirurgia , Sensibilidade e Especificidade
13.
Ann Clin Microbiol Antimicrob ; 23(1): 33, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622723

RESUMO

BACKGROUND: Antimicrobial resistance (AMR) is a major threat to children's health, particularly in respiratory infections. Accurate identification of pathogens and AMR is crucial for targeted antibiotic treatment. Metagenomic next-generation sequencing (mNGS) shows promise in directly detecting microorganisms and resistance genes in clinical samples. However, the accuracy of AMR prediction through mNGS testing needs further investigation for practical clinical decision-making. METHODS: We aimed to evaluate the performance of mNGS in predicting AMR for severe pneumonia in pediatric patients. We conducted a retrospective analysis at a tertiary hospital from May 2022 to May 2023. Simultaneous mNGS and culture were performed on bronchoalveolar lavage fluid samples obtained from pediatric patients with severe pneumonia. By comparing the results of mNGS detection of microorganisms and antibiotic resistance genes with those of culture, sensitivity, specificity, positive predictive value, and negative predictive value were calculated. RESULTS: mNGS detected bacterial in 71.7% cases (86/120), significantly higher than culture (58/120, 48.3%). Compared to culture, mNGS demonstrated a sensitivity of 96.6% and a specificity of 51.6% in detecting pathogenic microorganisms. Phenotypic susceptibility testing (PST) of 19 antibiotics revealed significant variations in antibiotics resistance rates among different bacteria. Sensitivity prediction of mNGS for carbapenem resistance was higher than penicillins and cephalosporin (67.74% vs. 28.57%, 46.15%), while specificity showed no significant difference (85.71%, 75.00%, 75.00%). mNGS also showed a high sensitivity of 94.74% in predicting carbapenem resistance in Acinetobacter baumannii. CONCLUSIONS: mNGS exhibits variable predictive performance among different pathogens and antibiotics, indicating its potential as a supplementary tool to conventional PST. However, mNGS currently cannot replace conventional PST.


Assuntos
Antibacterianos , Pneumonia , Humanos , Criança , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Estudos Retrospectivos , Farmacorresistência Bacteriana/genética , Sequenciamento de Nucleotídeos em Larga Escala , Carbapenêmicos , Sensibilidade e Especificidade , Líquido da Lavagem Broncoalveolar
14.
Head Face Med ; 20(1): 25, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641613

RESUMO

PURPOSE: To evaluate the accuracy of magnetic resonance imaging (MRI) for jawbone assessment compared to reference-standard measurements in the literature. MATERIALS AND METHODS: An electronic database search was conducted in PubMed, EMBASE, Scopus, Web of Science, and the Cochrane Library in June 2022, and updated in August 2023. Studies evaluating the accuracy of MRI for jawbone assessment compared with reference-standard measurements (histology, physical measurements, or computed tomography) were included. The outcome measures included bone histomorphometry and linear measurements. The risk of bias was assessed by the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). The review was registered in the PROSPERO database (CRD42022342697). RESULTS: From 63 studies selected for full-text analysis, nine manuscripts were considered eligible for this review. The studies included assessments of 54 participants, 35 cadavers, and one phantom. A linear measurement error ranging from 0.03 to 3.11 mm was shown. The accuracy of bone histomorphometry varies among studies. Limitations of the evidence included heterogeneity of MRI protocols and the methodology of the included studies. CONCLUSION: Few studies have suggested the feasibility of MRI for jawbone assessment, as MRI provides comparable results to those of standard reference tests. However, further advancements and optimizations are needed to increase the applicability, validate the efficacy, and establish clinical utility of these methods.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Sensibilidade e Especificidade
15.
Lancet Glob Health ; 12(5): e793-e803, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38583458

RESUMO

BACKGROUND: Tuberculosis, a major cause of death in people living with HIV, remains challenging to diagnose. Diagnostic accuracy data are scarce for promising triage and confirmatory tests such as C-reactive protein (CRP), sputum and urine Xpert MTB/RIF Ultra (Xpert Ultra), and urine Determine TB LAM Ag (a lateral flow lipoarabinomannan [LF-LAM] test), without symptom selection. We evaluated novel triage and confirmatory tests in ambulatory people with HIV initiating antiretroviral therapy (ART). METHODS: 897 ART-initiators were recruited irrespective of symptoms and sputum induction offered. For triage (n=800), we evaluated point-of-care blood-based CRP testing, compared with the WHO-recommended four-symptom screen (W4SS). For sputum-based confirmatory testing (n=787), we evaluated Xpert Ultra versus Xpert MTB/RIF (Xpert). For urine-based confirmatory testing (n=732), we evaluated Xpert Ultra and LF-LAM. We used a sputum culture reference standard. FINDINGS: 463 (52%) of 897 participants were female. The areas under the receiver operator characteristic curves for CRP was 0·78 (95% CI 0·73-0·83) and for number of W4SS symptoms was 0·70 (0·64-0·75). CRP (≥10 mg/L) had similar sensitivity to W4SS (77% [95% CI 68-85; 80/104] vs 77% [68-85; 80/104]; p>0·99] but higher specificity (64% [61-68; 445/696] vs 48% [45-52; 334/696]; p<0·0001]; reducing unnecessary confirmatory testing by 138 (95% CI 117-160) per 1000 people and number-needed-to-test from 6·91 (95% CI 6·25-7·81) to 4·87 (4·41-5·51). Sputum samples with Xpert Ultra, which required induction in 49 (31%) of 158 of people (95% CI 24-39), had higher sensitivity than Xpert (71% [95% CI 61-80; 74/104] vs 56% [46-66; 58/104]; p<0·0001). Of the people with one or more confirmatory sputum or urine test results that were positive, the proportion detected by Xpert Ultra increased from 45% (26-64) to 66% (46-82) with induction. Programmatically done haemoglobin, triage test combinations, and urine tests showed comparatively worse results. INTERPRETATION: CRP is a more specific triage test than W4SS in those initiating ART. Sputum induction improves diagnostic yield. Sputum samples with Xpert Ultra is a more accurate confirmatory test than with Xpert. FUNDING: South African Medical Research Council, EDCTP2, US National Institutes of Health-National Institute of Allergy and Infectious Diseases.


Assuntos
Infecções por HIV , Mycobacterium tuberculosis , Tuberculose Pulmonar , Tuberculose , Humanos , Feminino , Masculino , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/urina , Sistemas Automatizados de Assistência Junto ao Leito , Proteína C-Reativa , Estudos Prospectivos , Estudos Transversais , Sensibilidade e Especificidade , Tuberculose/diagnóstico , Tuberculose/tratamento farmacológico , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Escarro
16.
Proc Natl Acad Sci U S A ; 121(16): e2400203121, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38598338

RESUMO

Viral outbreaks can cause widespread disruption, creating the need for diagnostic tools that provide high performance and sample versatility at the point of use with moderate complexity. Current gold standards such as PCR and rapid antigen tests fall short in one or more of these aspects. Here, we report a label-free and amplification-free nanopore sensor platform that overcomes these challenges via direct detection and quantification of viral RNA in clinical samples from a variety of biological fluids. The assay uses an optofluidic chip that combines optical waveguides with a fluidic channel and integrates a solid-state nanopore for sensing of individual biomolecules upon translocation through the pore. High specificity and low limit of detection are ensured by capturing RNA targets on microbeads and collecting them by optical trapping at the nanopore location where targets are released and rapidly detected. We use this device for longitudinal studies of the viral load progression for Zika and Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) infections in marmoset and baboon animal models, respectively. The up to million-fold trapping-based target concentration enhancement enables amplification-free RNA quantification across the clinically relevant concentration range down to the assay limit of RT-qPCR as well as cases in which PCR failed. The assay operates across all relevant biofluids, including semen, urine, and whole blood for Zika and nasopharyngeal and throat swab, rectal swab, and bronchoalveolar lavage for SARS-CoV-2. The versatility, performance, simplicity, and potential for full microfluidic integration of the amplification-free nanopore assay points toward a unique approach to molecular diagnostics for nucleic acids, proteins, and other targets.


Assuntos
Nanoporos , Infecção por Zika virus , Zika virus , Animais , RNA Viral/genética , RNA Viral/metabolismo , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Primatas/genética , Zika virus/genética , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico
17.
PLoS Negl Trop Dis ; 18(4): e0012077, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38598549

RESUMO

BACKGROUND: Fever is the most frequent symptom in patients seeking care in South and Southeast Asia. The introduction of rapid diagnostic tests (RDTs) for malaria continues to drive patient management and care. Malaria-negative cases are commonly treated with antibiotics without confirmation of bacteraemia. Conventional laboratory tests for differential diagnosis require skilled staff and appropriate access to healthcare facilities. In addition, introducing single-disease RDTs instead of conventional laboratory tests remains costly. To overcome some of the delivery challenges of multiple separate tests, a multiplexed RDT with the capacity to diagnose a diverse range of tropical fevers would be a cost-effective solution. In this study, a multiplex lateral flow immunoassay (DPP Fever Panel II Assay) that can detect serum immunoglobulin M (IgM) and specific microbial antigens of common fever agents in Asia (Orientia tsutsugamushi, Rickettsia typhi, Leptospira spp., Burkholderia pseudomallei, Dengue virus, Chikungunya virus, and Zika virus), was evaluated. METHODOLOGY/PRINCIPAL FINDINGS: Whole blood (WB) and serum samples from 300 patients with undefined febrile illness (UFI) recruited in Vientiane, Laos PDR were tested using the DPP Fever Panel II, which consists of an Antibody panel and Antigen panel. To compare reader performance, results were recorded using two DPP readers, DPP Micro Reader (Micro Reader 1) and DPP Micro Reader Next Generation (Micro Reader 2). WB and serum samples were run on the same fever panel and read on both micro readers in order to compare results. ROC analysis and equal variance analysis were performed to inform the diagnostic validity of the test compared against the respective reference standards of each fever agent (S1 Table). Overall better AUC values were observed in whole blood results. No significant difference in AUC performance was observed when comparing whole blood and serum sample testing, except for when testing for R. typhi IgM (p = 0.04), Leptospira IgM (p = 0.02), and Dengue IgG (p = 0.03). Linear regression depicted R2 values had ~70% agreement across WB and serum samples, except when testing for leptospirosis and Zika, where the R2 values were 0.37 and 0.47, respectively. No significant difference was observed between the performance of Micro Reader 1 and Micro Reader 2, except when testing for the following pathogens: Zika IgM, Zika IgG, and B pseudomallei CPS Ag. CONCLUSIONS/SIGNIFICANCE: These results demonstrate that the diagnostic accuracy of the DPP Fever Panel II is comparable to that of commonly used RDTs. The optimal cut-off would depend on the use of the test and the desired sensitivity and specificity. Further studies are required to authenticate the use of these cut-offs in other endemic regions. This multiplex RDT offers diagnostic benefits in areas with limited access to healthcare and has the potential to improve field testing capacities. This could improve tropical fever management and reduce the public health burden in endemic low-resource areas.


Assuntos
Imunoglobulina M , Sensibilidade e Especificidade , Humanos , Imunoglobulina M/sangue , Feminino , Masculino , Laos , Adulto , Febre/diagnóstico , Anticorpos Antibacterianos/sangue , Testes Diagnósticos de Rotina/métodos , Pessoa de Meia-Idade , Adolescente , Adulto Jovem , Anticorpos Antivirais/sangue , Antígenos de Bactérias/imunologia , Antígenos de Bactérias/análise , Imunoensaio/métodos , Imunoensaio/normas
18.
BMJ Open ; 14(4): e080285, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38626962

RESUMO

OBJECTIVE: To analyse the effectiveness of rapid diagnostic clinics (RDCs) as an alternative pathway for patients with concerning symptoms and a faecal immunochemical test (FIT) result <10. Our primary endpoint was rate of colorectal cancer (CRC) detection. Second endpoints were rates of other cancers and gastrointestinal (GI) serious benign conditions. Finally, we analysed the specific pathway followed by FIT <10 patients with cancer at Guy's and St Thomas NHS Foundation Trust (GSTT) RDC. DESIGN: A retrospective and prospective cohort study. SETTING: GSTT RDC, one of England's largest single-centre RDCs. Sociodemographic and clinical characteristics of FIT <10 patients were analysed descriptively. PARTICIPANTS: Patients with an FIT result <10, seen at GSTT RDC between 1 January 2020 and 5 May 2023. RESULTS: A total of 1299 patients with an FIT<10 were seen at GSTT RDC between January 2020 and May 2023. Of these, 66% (n=861) reported weight loss, 62% (n=805) pain, 37% (n=481) fatigue, 34% (n=444) were anaemic and 23% (n=301) had nausea and vomiting. Among these patients, 7% (n=88) received a cancer diagnosis, 36% (n=462) were identified as having a serious benign condition. Within the patients with cancer, 9% (n=8) were diagnosed with CRC. Among patients with serious benign conditions, 7% (n=31) were referred to colorectal, hepatopancreatobiliary, or upper GI specialists. CONCLUSION: This study demonstrates the effectiveness of RDCs as an alternate pathway for FIT <10 patients with ongoing clinical concerns. These results contribute to enhancing patient care and optimising resource allocation within the healthcare system.


Assuntos
Neoplasias Colorretais , Humanos , Sensibilidade e Especificidade , Neoplasias Colorretais/diagnóstico , Estudos Retrospectivos , Estudos Prospectivos , Testes de Diagnóstico Rápido , Sangue Oculto , Detecção Precoce de Câncer/métodos , Colonoscopia , Fezes/química , Hemoglobinas/análise
19.
BMC Res Notes ; 17(1): 108, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637887

RESUMO

OBJECTIVE: Considering the importance of endometriosis and its relatively high prevalence among women, this study sought to investigate clinical and Transrectal and transvaginal ultrasounds (TVS) findings of disease. METHODS: This descriptive-analytical study was performed based on medical records of 155 women with endometriosis admitted to Rasool-e Akram Hospital in Tehran for a TVS. All the sonography data and patients' information were collected into checklists and analyzed in SPSS-25 software (IBM). RESULTS: The mean age of participants was 32.4 ± 6.1 years, ranging from 18 to 50 years. Endometrioma was prevalent in 129 patients (84.8%). Size of endometrioma (diameter) was more than 3 cm in 79.9% of patients, and 3 cm or fewer in 20.1% of cases. Bladder, intestinal, vaginal, and rectosigmoid involvements with endometriosis implants were observed in 4 (2.6%), 54 (35.5), 3 (0.2%), and 51 (33.5) of patients, respectively. A total of 64.5% of patients were diagnosed with incomplete stenosis of the Douglas pouch and 35.5% had complete stenosis. Deep infiltrating endometriosis (DIE) was less than 1 cm in 20.7%, 1 to 3 cm in 42.3%, and over 3 cm in 37% of patients. The most common manifestations of endometriosis Obliteration of the Douglas pouch, endometrioma, and DIE. In addition, imaging modalities have shown promising results, indicating the necessity to use transvaginal ultrasound as the first line of diagnosis in patients with clinically suspected endometriosis.


Assuntos
Endometriose , Humanos , Feminino , Adulto , Endometriose/diagnóstico por imagem , Constrição Patológica , Sensibilidade e Especificidade , Irã (Geográfico) , Diagnóstico por Imagem , Ultrassonografia/métodos
20.
BMC Vet Res ; 20(1): 152, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654224

RESUMO

BACKGROUND: Chronic wasting disease (CWD) is a prion disease of captive and free-ranging cervids. Currently, a definitive diagnosis of CWD relies on immunohistochemistry detection of PrPSc in the obex and retropharyngeal lymph node (RPLN) of the affected cervids. For high-throughput screening of CWD in wild cervids, RPLN samples are tested by ELISA followed by IHC confirmation of positive results. Recently, real-time quacking-induced conversion (RT-QuIC) has been used to detect CWD positivity in various types of samples. To develop a blood RT-QuIC assay suitable for CWD diagnosis, this study evaluated the assay sensitivity and specificity with and without ASR1-based preanalytical enrichment and NaI as the main ionic component in assay buffer. RESULTS: A total of 23 platelet samples derived from CWD-positive deer (ELISA + /IHC +) and 30 platelet samples from CWD-negative (ELISA-) deer were tested. The diagnostic sensitivity was 43.48% (NaCl), 65.22% (NaI), 60.87% (NaCl-ASR1) or 82.61% (NaI-ASR1). The diagnostic specificity was 96.67% (NaCl), 100% (NaI), 100% (NaCl-ASR1), or 96.67% (NaI-ASR1). The probability of detecting CWD prion in platelet samples derived from CWD-positive deer was 0.924 (95% CRI: 0.714, 0.989) under NaI-ASR1 experimental condition and 0.530 (95% CRI: 0.156, 0.890) under NaCl alone condition. The rate of amyloid formation (RFA) was greatest under the NaI-ASR1 condition at 10-2 (0.01491, 95% CRI: 0.00675, 0.03384) and 10-3 (0.00629, 95% CRI: 0.00283, 0.01410) sample dilution levels. CONCLUSIONS: Incorporation of ASR1-based preanalytical enrichment and NaI as the main ionic component significantly improved the sensitivity of CWD RT-QuIC on deer platelet samples. Blood test by the improved RT-QuIC assay may be used for antemortem and postmortem diagnosis of CWD.


Assuntos
Plaquetas , Cervos , Sensibilidade e Especificidade , Doença de Emaciação Crônica , Animais , Cervos/sangue , Doença de Emaciação Crônica/diagnóstico , Doença de Emaciação Crônica/sangue , Plaquetas/química , Ensaio de Imunoadsorção Enzimática/veterinária , Príons/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...